5.1 PANEL DESCRIPTION
5.1.1 The Company commercial high rib panels
shall provide 36" net coverage on walls and roof with lengths up to
34'. The panels shall have 4 major ribs, 12" on center, 1¼"
deep. Trapezoidal return ribs to taper from 1" to 3-15/16"
with intermediate shoulders and an anti-capillary flute (Siphon
Groove) at the last rib with purlin bearing leg. Two
secondary ribs shall be formed between the major ribs. Panels
shall be overlapped one major rib at the sides. End laps
shall be a minimum

of six inches. Mastic sealant shall be provided at all side
laps and end laps on roof. Note: Roof standard is Galvalume.
If colored roof panels are specified there will be an additional
charge.5.1.1 Architectural commercial wall panel
shall provide 36" net coverage for walls, in lengths up to
34'. Ribs are 1-1/8" deep and spaced 12" on center.
Panel design semi-conceals fasteners, while providing a shadow line
appearance. Side laps shall be on full major
corrugation.
5.1.2 Concealed fastener standing seam roof
systems are available upon request. Concealed fastener wall panels
are available upon request.